Training Materials for Olympus Endoscopes
In-depth education and continuous learning are key factors for safe endoscope reprocessing.
Olympus is dedicated to providing a variety of training and support materials that can be used in daily practice and education.
No results found.
Please change the filter in order to get a result!
No filter set.
Please set the filter in order to get a result!
BF, LF, ENF - OnTrack Reprocessing - US
BF-UC180F - OnTrack Reprocessing - US
CF, PCF, GIF, SIF - OnTrack Reprocessing - US
OER-Pro - OnTrack Reprocessing - US
TJF-Q190V - OnTrack Reprocessing - US
TJF-Q180V - OnTrack Reprocessing - US
Ultrasonic Gastrovideoscopes - OnTrack Reprocessing - US
Video Bronchoscopes - OnTrack Reprocessing - US
Sampling and Culturing of Flexible Endoscopes - GLOBAL
Microbiology: The Basics of Bacteria - GLOBAL
Reprocessing Basics Thermolabile Endoscopes - EMEA
Reprocessing Basics of Heat Stable Medical Devices - EMEA
Reprocessing of Endoscopic Components & Accessories - EMEA
Reprocessing URO Endoscopes & Accessories - EMEA
Reprocessing Chemicals - EMEA
Water - EMEA
PCF-H190TL/I, PCF-H290TL/I - Manual Reprocessing - EMEA
Pre-Cleaning
Leakage Testing
Manually Cleaning
(01:03 - 01:34) Clean the external surfaces of the insertion section
(01:35 - 02:23) Clean external surfaces of control section, surrounding parts
(02:24 - 02:59) Clean external surfaces of endoscope connector, universal cord
(04:25 - 05:27) Brush from suction cylinder to endoscope connector
(06:44 - 08:09) Aspirate detergent solution through instrument/suction channel
(08:10 - 10:28) Flush air/water channel with detergent solution
(10:29 - 11:30) Flush auxiliary water channel with detergent solution
(11:31 - 12:16) Immerse endoscope, accessories in detergent solution
Manual Disinfection
Rinsing
Storage
TJF-Q190V, TJF-Q290V - Manually Cleaning - EMEA
Manually Cleaning
(02:55 - 03:59) Brush bottom of forceps elevator, groove, foreceps elevator recess, from back
(04:00 - 04:37) Brush lens side surface of distal end, distal ring
(05:02 - 05:58) Brush left side surface of distal end, distal ring
(05:59 - 06:50) Brush right side surface of distal end, distal ring
(06:51 - 07:27) Brush back side surface of distal end, distal ring
(08:07 - 08:44) Brush from suction cylinder to endoscope connector
(12:46 - 13:38) Aspirate detergent solution through instrument channel, suction channel
(13:39 - 13:58) Flush air/water channel with detergent solution
(13:59 - 14:33) Immerse endoscope and accessories in detergent solution
(17:48 - 18:21) Remove detergent solution from distal end flushing adapter
BF-UC190F, BF-UC290F - Manually Cleaning - EMEA
BF-UC190F, BF-UC290F - Manually Cleaning - NON EMEA, NON US
BF-UC190F - Manually Cleaning - US
OER-AW with TJF-Q190V - Automated Reprocessing - EMEA
OER-Pro with TJF-Q190V - Automated Reprocessing - US
Bronchoscope Cleaning Guide - EMEA
Bronchoscope Cleaning Guide - US
Bronchoscope Disinfection Guide - US
BF-UC180F, UC260FW - Endoscope Cleaning Guide - EMEA
BF-UC180F, UC260FW - Endoscope Cleaning Guide - US
BF-UC190F, 290F - Endoscope Cleaning Guide - GLOBAL
EVIS X1, EXERA, LUCERA - Endoscope Pre-Cleaning Guide - NON US
EVIS X1, EXERA, LUCERA - Endoscope Manual Cleaning Guide - NON US
EVIS X1, EXERA, LUCERA - Endoscope Leakage Testing Guide - NON US
EVIS X1, EXERA - Endoscope Pre-Cleaning Guide - US
EVIS X1, EXERA - Endoscope Manual Cleaning Guide - US
EVIS X1, EXERA - Endoscope Leakage Testing Guide - US
GI Endoscope Pre-Cleaning Guide - US
GI Endoscope Cleaning Guide - US
GI Endoscope Disinfection Guide - US
MAJ-891 - Reprocessing Endoscope Accessories - EMEA
MAJ-891 - Reprocessing Endoscope Accessories - US
MAJ-2092 - Reprocessing Endoscope Accessories - EMEA
MAJ-2092 - Reprocessing Endoscope Accessories - US
OER-Elite with GI Endoscopes - Modified Manual Cleaning Steps - US
OER-AW, OER-Pro with TJF-Q190V - Automated Reprocessing - EMEA
OER-AW, OER-Pro with TJF-Q170V - Automated Reprocessing - EMEA
OER-PRO with GI Endoscopes - Reprocessing Guide - US
TJF-Q180V - Endoscope Cleaning Workflow - US
TJF-Q180V - Endoscope Disinfection Workflow - US
TJF-Q190V - Endoscope Cleaning Guide - EMEA
TJF-Q190V - Endoscope Cleaning Guide - US
Ultrasound Endoscope Cleaning Guide - US
Ultrasound Endoscope Disinfection Guide - US
For additional support material please also explore our Olympus On-Demand Library:
https://www.olympusprofed.com/reprocess
All wallcharts are designed as a quick refence guide only. It is not a substitute for reading the entire Operators Manual and/or Instruction For Use (IFU). Olympus cannot encourage or recommend any actions that deviate or are not covered by the IFU.